Overview
Metis polls the device's SNMP agent every 30 seconds with GET and GETBULK only; it never writes. Problems join the Health page, the reports and alerts like any other system. The free edition watches one SNMP device; paid editions are unlimited.
SNMP v1, v2c and v3 (user, authentication and encryption) are supported. The device must allow the dashboard's address in its SNMP access list.
Add devices
- Open Devices.
- Find devices scans your network over UDP 161: each address is asked for its system name with the communities you list (default
public), and for an SNMPv3 engine if none answers. Press Add beside a result, or Add all. - Or Add device: address, version, community (v1, v2c) or user and passphrases (v3). Test connection, Save.
Credentials are stored encrypted. A scan accepts a range such as 192.168.1.10-50 and covers at most 4096 addresses. A device that answers only SNMPv3 is listed and needs a user before it can be added.
What is read
Metis tries the standard MIBs on every device and shows what the device has:
- Ports (IF-MIB): status, speed, in and out rate, errors, load. A port that is down is not a problem; a port that is up and logging 1 or more errors a second is.
- CPU, memory and volumes (HOST-RESOURCES-MIB).
- UPS (UPS-MIB; APC PowerNet on older APC cards): battery state and charge, runtime, load, voltages, alarms. On battery is a warning; low or depleted battery, or 5 minutes or less left, is critical.
- Printers (Printer-MIB): supplies and the printer's error flags. A supply at 10% or less is a warning; empty, out of paper or a jam is critical.
- Temperatures, fans and power (ENTITY-SENSOR-MIB): a temperature of 85 °C is a warning, 100 °C critical.
- Synology NAS: system, fans, power, disk status and temperature, RAID volume state.
History and statistics
A device keeps no history of its own, so the dashboard writes down what it reads once a minute and stores it the way an agent stores a machine's: every reading for 3 days, then quarter-hour averages (with the lowest and highest) for 30 days, then one summary a day for ever. It records CPU, memory, the hottest temperature, UPS battery, load, runtime and voltage, the fullest volume, traffic through the ports that are up (a switch counts a packet on the way in and again on the way out), pages printed per hour and the lowest supply level. All of it together is limited to 100 MB, and the older detail is thinned first if there are very many devices. History starts from when the device was added or the dashboard was updated.
A device's page has Overview, History (a chart for each reading, from 1 hour to 1 year) and Statistics (now, average, median, middle half, lowest and highest for each reading, and a box for each few hours of the day). A hypervisor has the same two tabs for each host, and a server management controller (BMC) for each of its sensors. The charts can be copied or saved like any other. Processor, memory and temperature are also on the Compare page.
Enable SNMP on the device
Turn on the SNMP service on the device and give it a read-only community or user.
On a Synology: Control Panel, Terminal & SNMP, SNMP. Use a read-only community that is not public when the device is reachable beyond your own network.
Not yet tried on real hardware. Metis has been tested only against simulated devices. If a device is not read correctly, tell us its make and model.
Something missing or unclear? Ask us.